STALIF MIDLINE®

No-Profile® Anterior Lumbar Integrated Interbody System

STALIF MIDLINE® is part of an “integrated” system of implants and instruments designed to create consistent clinical results and avoid more destructive multiple incision surgeries.

Designed to simplify surgery and reduce the number of surgical steps required.

No Supplemental Fixation
Integrated cage and screw system is cleared for use without supplemental fixation. Some surgeons, however, may still choose to use plates or pedicle screws.

Conforms to Patient Anatomy
The "No-Profile" design allows it to nest fully within the confines of the vertebral body, leaving the anatomy unchanged external to the interbody.
Compressive Fixation Ensures Graft and Endplate Contact As the preferred design to ensure fixation in cancellous vertebral bone, cancellous screws—combined with our screw head design—produce a lag effect between the vertebral body and the implanted device.
The lag effect provides constant compressive forces against the implant, which results in a greater interface between the graft and the endplate to facilitate the fusion process.
Engineered to Maximize Opportunities for Fusion The 3-screw design utilizes a midline convergence pattern in conjunction with an optimal horizontal inclination. These integrated elements conform to AO principles of fracture fixation, increasing the possibility of a fusion2.
Stalif C (No-Profile® Anterior Cervical Integrated Interbody System)

STALIF C® is part of an “integrated” system of implants and instruments designed to create consistent clinical results and avoid more destructive multiple incision surgeries.

Efficient Design. Fewer, Simpler Surgical Steps
STALIF C® was designed to simplify surgery and reduce the number of surgical steps required.

No Supplemental Fixation
STALIF C's integrated cage and screw system is cleared for use without supplemental fixation. Some surgeons, however, may still choose to use anterior plates or posterior fixation.

No-Profile®.

Conforms to Patient Anatomy
The STALIF C® “No-Profile” design allows it to nest fully within the confines of the vertebral body, leaving the anatomy unchanged external to the interbody.

The Lag Effect.

Compressive Fixation Ensures Graft and Endplate Contact
As the preferred design to ensure fixation in cancellous vertebral bone, cancellous screws combined with our screw head design produce a lag effect between the vertebral body and the implanted device.
The lag effect provides constant compressive forces against the implant which results in a greater interface between the graft and the endplate to facilitate the fusion process.

Optimal Screw Trajectories.

Engineered to Maximize Opportunities for Fusion
The STALIF C® 3-screw design utilizes a midline convergence pattern in conjunction with an optimal horizontal inclination. These integrated elements conform to AO principles of fracture fixation, increasing the possibility of a fusion2.
Our Services Include
  • Market Research
  • Clinical Research
  • Product R&D
  • Marketing
  • Registration
  • Distribution
  • Training
  • Operations

Our Clients

3848 S.W. 30th Avenue, Fort Lauderdale, Florida 33312     |     Phone: (954)327.1447     |     Fax: (954) 587.0384     |     Email: info@traatek.com

CONTACT TRAATEK

Copyright © 2018 traatek.com | All Rights Reserved